modul bazowy

Base module

Building structure:

  • Improved diagnostics of Slabs intersecting the Roof element
  • Acceleration and optimization of the algorithm responsible for Computation of building structure

 

Presentation of the elements, common functions:

  • Possibility to hide unused edit scopes in a given project (e.g. Ceiling and Loop drawings-ceiling in projects containing only underfloor heating)
  • Change of default position of labels for selected elements on plan views (watch the movie)
  • Modification of the styles of elements of the following types: Roof, Ground, Dormer, Slab for 2D editor in terms of color and drawing line type
  • Clarification of hints for elements defined in the General data window, on the Storeys management tab, in the Position and Sizes sections
  • Improved display of colors in dark mode
  • Additional 3D view window for the needs of:
    • BIM modules (import and interpretation)
    • Creation of building structure and execution Thermal calculation of building
    • Optimizing the design of different types of installations in one project
  • Two new commands Visible in 3D view (alt+1) / Hide in 3D view (alt+2) which:
    • Responsible for the visibility of elements in 3D view (applies to elements in the scope Underlay (IFC) and Construction, which have the Visible field in Data table)
    • They improve the ergonomics of hiding IFC elements, which are not to be later interpreted into native elements of the structure
    • They have been added as default functions under the right mouse button (Popup menu) and have hotkeys assigned by default
  • Improved operation of Generate schematic view algorithm for direction of generated branches
  • Improved the Export DWG/DXF file function
  • Ability to give names to the exported DWG/DXF files, which  e.g facilitates the export of drawings with different ranges of exported layers from the program.
  • Search in certain fields in the General Data window

 

  • Update of product catalogues
IFC interpretacja danych budynku

IFC (BIM) import basis / IFC (BIM) building data interpretation

  • Reorganization of the icons for importing the IFC model, creating a storeys based on an IFC file and interpreting elements from an IFC file
  • Import and interpretation of the ifcSpace element via the Creates rooms from an IFC file function (watch the movie)
    • The new function creates native elements of the InstalSystem 5 package of the Room (Manual) type in the editing scope Construction
    • The function transfers the Description and Symbol assigned by the architect to the newly created room
    • The newly created room can be further modified, including changing its shape, position, division or deletion
    • The spaces created in this way can be further used to generate structural partitions using the Automatic walls, ceilings and roofs function as an alternative (or supporting) path for obtaining thermal partitions based on the interpretation of structural elements from the IFC file
  • New search criteria for the Search window - Underlay scope:
    • Invisible (inactive/hidden) - allows you to select and display IFC elements that have been hidden and thus are not subject to interpretation
    • Top surface greater than - a criterion that facilitates finding ifcSlab, ifcRoof elements that can define storeys when using the function: Create storeys between selected slabs/roofs from IFC file
  • Correction of wall geometry - Correct wall connections removes self-contained walls, which may result from defining walls that contain one another in the IFC model and their subsequent interpretation in the program to native elements such as Wall / Curtain wall
eksport konstrukcji budynku dostepny wkrotce

IFC (BIM) building structure elements export

  • Extending the scope of exported construction elements with ifcSpace (watch the movie)
    • Export of Room (Manual) / Room (Automatic) elements existing in the project (also previously interpreted from ifcSpace objects)
    • Parameterization of exported rooms in terms of technical and calculation data (several parameters with units)
  • Supplement with technical and calculation parameters of the ifcBuilding element
eksport instalacji grzewczej i chlodzacej IFC

IFC (BIM) heating/cooling/tap water system export

  • Parameterization of the IFC4 export of elements of the following types: RHC loop, Double apartment manifold, Valve in the range Heating systems, Cooling systems, Water systems. The listed items are exported along with:
    • Technical parameters
    • Calculation parameters
      thus supplementing the existing parameterization of the Pipe-run element (including Pipe feed and Riser) and the entire Radiant systems module (watch the movie)
eksport instalacji kanalizacyjnej IFC

IFC (BIM) sewage system export

eksport instalacji wodociagowej IFC

IFC (BIM) heating/cooling/tap water/sewage system export

  • All items are exported with the catalog number of a given item as CatalogCode if they contain such a catalog code (watch the movie)
systemy grzewcze

Heating systems

  • Possibility to generate a list of installation elements per storey or per building unit (watch the movie)
  • Change of diagnostics message "Control valve does not provide proper pressure for circuit supplied (avail. press. > ??)" priority from error to warining
  • In the label of a Pipe-run element the ordinate at the point of the label can be presented. The value presented depends on the insertion point on the pipe-run
  • The Differential pressure controller has the possibility of defining a so-called "successor" with regard to the range of the stabilised differential pressure. If it is not possible to obtain the required differential pressure from the type indicated in the data, the program tries to select a successor
  • In the general data: Distribution system / Types and default data, declare the default type of manifold, which will be taken for the double manifolds inserted into the range Convectional. These manifolds may be not from catalogues, or from pipe and fitting catalogues, where manifold kits and cabinets may be declared for them, as for manifolds for radiant systems
  • The data of a Riser element, changed in the data table before its insertion, automatically becomes the default data of any subsequent
  • New functions Copy selected elements to multiple storeys above and Copy selected elements to multiple storeys below (watch the movie)
  • New Reduction point element available on the ribbon in the Distribution - thermal installations group allows to reduce the flow in the installation (from the place of its insertion towards the source)
systemy chlodnicze

Cooling systems

  • Possibility to generate a list of installation elements per storey or per building unit (watch the movie)
  • New Reduction point element available on the ribbon in the Distribution - thermal installations group allows to reduce the flow in the installation (from the place of its insertion towards the source)
straty ciepla

Heat loss

  • New DIN / TS 12821-1: 2020-04 standard (BETA version) available in the selected packages
systemy plaszczyznowe

Radiant systems

  • Possibility to generate a list of installation elements per storey or per building unit (watch the movie)
  • Possibility to set minimum flow velocity in a loop, separately for floor, wall and ceiling systems (watch the movie)
  • Possibility to set and modify the supply temperature directly in the Interactive radiant systems calculations window (watch the movie)
  • New column in the Interactive radiant systems calculations window informing about the character of the flow (laminar/turbulent) (watch the movie)
  • Possibility to set in the Interactive radiant systems calculations window a temperature drop beyond the limit values ​​defined in the general data or set individually for the edited Heating/Cooling Zone
  • New tool Cutting holes for cutting out fragments inside floors or ceilings (for kitchen islands, columns etc.) (watch the movie)
  • Unified method of determining the distance of the first pipe-feed and the first loop from the edge of Heating/Cooling zone.
  • New type of element Heating/cooling floor zone: With return temp. limiter fed from radiator return. Must be fed from the radiator return in the same room using the Serial connection element, and is not subject to automatic subdivision. There must be a return temperature limiter on the return pipe-run to the source (watch the movie)
systemy panelowe

Panel systems

  • The Wall panel does not offer the possibility of mirror reflection ("Flip") and has a visually distinguished plane facing the room
  • In the data sheet of the Wall panel element it is possible to block its rotation in the vertical plane, in order to ensure that in the project the panel is always oriented in accordance with the manufacturer's requirements
ulozenie plyt systemu suchego

Dry system boards arrangement

  • Thorough improvement of the module in order to improve the ergonomics and speed of arranging boards of the dry system (watch the movie) by:
    • new function that automatically fills the indicated area with boards of a given type
    • better control of the selection of the snap point (coarse or more precise)
    • graphic indication of an active snap point
    • possibility to rotate the board before inserting
    • the possibility of precise shifting or adjusting the inserted boards in relation to the horizontal and vertical axis
    • possibility of precise cutting of boards fragments
  • Improved alignment of automatically generated loop drawings with the grooves in the boards (watch the movie)
stacje mieszkaniowe

Flat stations

  • New dedicated print page Elements in flat stations enabling the analysis of routes and hydraulic circuits inside flat station (watch the movie)
  • Calculations and presentation in the results the required heat output of the source supplying flat stations during the summer period (watch the movie)
  • Improved determination of the required minimum pressure ahead flat station
instalacje wodociagowe

Tap water systems

  • Possibility to generate a list of installation elements per storey or per building unit (watch the movie)
  • In the label of the Pipe-run element it is possible to present the ordinate at the point of the label. The presented value depends on the label insertion point on the pipe-run
  • Possible connection the element Expansion vessel to cold water pipe-runs
  • The data of the Riser element, changed in the data table before its insertion, automatically becomes the default data of any subsequent riser
  • New functions Copy selected elements to multiple storeys above and Copy selected elements to multiple storeys below (watch the movie)
instalacje kanalizacyjne dostepny wkrotce

Domestic wastewater gravity systems

  • A connection point between pipe-runs is named Junction and has its own data table specifying how it is implemented (built of available fittings)
  • A Junction can have an inserted label. The label can show the fittings which form the connection
  • The fittings selected in Junction elements can, if correctly selected, be visualised in the model or in a projection, in a simplified or natural way. This requires the use of an adapted catalogue of pipes and fittings, with extended information on the dimensions of the fittings. Such catalogues are highlighted by a special icon when selecting catalogues for the project. The visualisation is activated in the project general data: Component appearance configuration Drawing options (watch the movie)
  • In the label of a Pipe-run element, the ordinate at the point of the label can be presented. The value presented depends on the label insertion point on the pipe-run, which is important because of the occurrence of pipe-runs gradients. The ordinates and distances from the floor for the start and end point of the pipe-run are also available
  • The field Maximum gradient has been added to the data table of the <Pipe-run> element. In "Auto" mode it is taken from the general project data. By changing it individually for selected pipe-runs, it is possible to avoid the short vertical sections generated in some places while maintaining a single maximum gradient
  • Element Stack added to Project Viewer module
  • Clearer and supplemented with arguments (e.g. value of required angle) messages about missing (not sized) elements of the junctions
  • Data of the element Stack, changed in the data table before its insertion, becomes automatically the default data of each following one
  • New element Connection of other drainage installation allows faster creation and recalculation of large projects with repetitive plumbing blocks (but their components are not included in the bill of materials)
  • The Stack element in the Drainage , Drainage ventilation configuration has the possibility of automatically generating pipe-runs which form the structure of a parallel ventilation: connectors between the drainage and ventilation sections, an additional riser on the lowest floors, etc. The necessary geometrical parameters must be defined in the stack data table. This function requires the connection of the stack to the waste water network and the connection of the sanitary appliances. This feature is in Beta stage and will be further developed  (watch the movie)
  • New functions Copy selected elements to multiple storeys above and Copy selected elements to multiple storeys below (watch the movie)
przetwarzanie zestawienia materialow

Material list processing

  • Improved sorting of Bill of materials after export to UGS format
  • GAEB export - included dimension/diameter information